• Home
  • TECHNOLOGIES
  • Environmental Specs

Environmental Specs

 

OPERATING

NON-OPERATING

Temperature:

-40° C to +85° C

-40° C to +85° C

Humidity

No Conformal Coating:

0% to 95% non-condensing @ 60°C

0% to 95% non-condensing @ 60°C

With Conformal Coating:

0% to 95% condensing @ 60°C

0% to 95% condensing @ 60°C

Altitude (per MIL-STD-810G Method 520.3; DO-160D Section 4.6.1)

Lithium Coin Battery Not Used:

50,000 Feet

1. Based on adequate enclosure

2. If convection cooled units selected, external fan is required.

VIBRATION (per MIL-STD-810G Method 514.5 and 520.3; DO-160D Section 8.0; MIL-STD-167-1 (5 to 50Hz)

Spectrum [Hz]:

5-2000

5-2000

Acceleration (RMS):

8g

8g

Duration:

30 minutes per axis

30 minutes per axis

Shock (per MIL-STD-810G Method 516.6 and 520.3; DO-160D Section 7.0; MIL-STD-901D Grade A; MIL-STD-202, Method 213,

test condition K (30G sawtooth)

Amplitude:

100g

60g

100g

60g

Duration:

15ms

30ms

15ms

30ms

Hits:

3 per axis

3 per axis

3 per axis

3 per axis

Power Input:

Systems with Power Conditioning

Module Option

Per DO-160D Sections 16,17, MIL-STD-1275

Salt/Fog:

Conformal Coated products Only

Per MIL-STD-810G Method 509.5; DO-160D Section 14.0; MIL-STD-202,

Method 101 test condition B (48 hrs)

Fungus:

Conformal Coated products Only

Per MIL-STD-810G Method 508.6; DO-160D Section 13.0; MIL-STD-454 group 1,

requirement 4

Water Dripping:

Conduction Cooled & Sealed Only

Per MIL-STD-810G Method 506.5; DO-160D Section 10.0

EMI

All Systems

Radiated emission standard Class A EN61326:1997, A1:1998, A2:2001

Systems with Power

Conditioning Module Option

Per MIL-STD-461E Methods CS-114 Curve 5, CS-115, CS-116 and RS103

Conduction Cooled & Sealed Only

(display excluded)

Radiated emissions per FCC Class A and EN 55022-A

Notes:
- Rotating Media (HDD) not included in these specs.
- Max operating temperature will vary based on type of cold plate mounting and CPU maximum operating speed configurations
- Acceleration (8g) is limited by SSDs
- The GMS Ruggedization Level 5 is designed to meet this table